Compact full anechoic chamber

Compact full anechoic chamber

The compact full anechoic chamber can be used to evaluate the radiant immunity test at 3m distance. For products suitable for the 1.5m*1.5m test area, these tests conform to the IEC / EN 61000-4-3 standard. In addition to these immunity tests, the radiation emission pre-test can be carried out in a repeatable environment.

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description
The compact full anechoic chamber can be used to evaluate the radiant immunity test at 3m distance. For products suitable for the 1.5m*1.5m test area, these tests conform to the IEC / EN 61000-4-3 standard. In addition to these immunity tests, the radiation emission pre-test can be carried out in a repeatable environment.

Features of a compact full anechoic chamber:
Fully compliant immunity test site with frequency range from 80MHz to 18GHz.

Inner lining polystyrene absorbers to ensure a stable and uniform environment.

Pre-test for radiation emission at 3m distance.

Standard/test method for a compact full anechoic chamber:

IEC/EN 61000-4-3

CISPR-16-1-4 (only for pre-test)

Typical performance of a 3m semi anechoic chamber:

FSNSA: 3m test distance 30-200MHz≤+/- 6.0dB; 200-1000MHz≤+/- 4dB

sVSWR: 3m test distance≤6dB

FU: 75% of 16 points ≤ 6dB at 3m test distance & 1.5*1.5m test window (0.8m above floor level)
Specifications

External dimensions

7.6m*3.7m*3.6m(L*W*H)

Dimensions

7.0m*3.1m*3.0m(L*W*H)

Construction

2mm galvanized shielding panels with a free standing structural steel support

Absorbers

Hybrid solution of ferrite tiles and polystyrene hybrid absorber on walls, floor and ceiling

Ventilation

300mm*300mm/18GHz

Shielded door

RF shielded swing door 0.9m*2.1m(W*H)

Ground interface board

400mm*400mm/18GHz, including RF connectors

EUT power line

Filtered 220V 32A 50Hz/60Hz; 380V 63A 50Hz/60Hz

Lighting

No-interference LED automatic lifting and lighting system

Frequency range

80MHz to 18GHz for radiated immunity and 30MHz to 18Ghz for radiated emission

Test distance

3m between center of antenna and EUT

FU

1.5m*1.5m

Floor

Carpet laying on the surface of the full anechoic chamber (ground ferrite).

In addition to the typical specifications of compact full anechoic chamber, RFT can also customize the anechoic chamber configuration for customers according to the size of quiet zone and the type of test standard.

Compact full anechoic chamber options:

Fully compliant with radiated immunity test for frequency range from 26MHz to 18GHz.

An additional shielded room can be installed to accommodate high power RF power amplifiers (amplifier room) or control and test equipment (control room).

Turntable for pre-testing of radiation emissions.

CONTACT US